Sodium-ion batteries require tailored monitoring strategies
A battery management system (BMS) must be able to reliably assess, at all times, the conditions under which a cell is operating and how its state is changing. Voltage, current, and surface temperature are key parameters for this purpose. However, they do not necessarily provide a direct reflection of all processes occurring inside the cell.
For sodium-ion batteries, monitoring and diagnostic methods must be adapted to the cell chemistry, electrode materials, cell design, and operating profile. Simply applying established assumptions from lithium-ion systems without verification is insufficient for this purpose.
Better Understanding of Internal Cell Processes
Internal cell sensors can capture additional information directly from the cell. External sensors complement this perspective by providing accessible measurements at the cell or module level.
The central research question is therefore: Which additional sensor signals actually provide robust and diagnostically relevant information about the operation and aging of a sodium-ion cell?
The key is not to use the largest possible number of sensors. What is crucial is identifying relevant parameters and demonstrating their additional informational value under defined operating and aging conditions.
Evaluating Cell States More Thoroughly
Combining additional sensor signals with voltage, current, temperature, and electrochemical measurements is intended to create a broader data foundation for interpreting cell behavior.
In the future, this data can be used to estimate battery status, perform diagnostics, and detect abnormal cell conditions. Whether—and to what extent—this improves, for example, the determination of state of charge or battery health must be validated experimentally.
Integrating Cell and BMS Development
This work is embedded in the ongoing sodium-ion development efforts of the SIB:DE Development project. There, electrodes are developed, fabricated, and characterized, and selected approaches are transferred to pouch-type full cells.
This allows sensor technology and monitoring to be investigated directly on cells whose materials, manufacturing, and electrochemical behavior are known within the development process.