High-speed MEMS micromirrors with a wide field of view

Wide Field of View and High Scan Rates in a Compact Scanner

LiDAR, laser projection, and other optical systems require wide scan angles and high scanning frequencies. At the same time, mirrors must provide a sufficiently large optical aperture while remaining compact, energy-efficient, and mechanically robust. Some of these requirements involve direct technical trade-offs: high stiffness supports fast motion but makes large deflections more difficult to achieve.

Gas damping presents an additional challenge. In resonant micromirrors, it limits the achievable amplitude and can require higher drive voltages. Large scan angles also increase mechanical stress, making shock and vibration resistance as well as service life important development parameters.

Optical integration also places demanding requirements on the system. Reflections from the package window can interfere with projection and measurement. For applications such as LiDAR or augmented reality, the scanner, packaging, and optical system therefore need to be considered together.

This is particularly relevant for solid-state LiDAR, compact laser projection systems, industrial laser scanners, and optical measurement systems.

From MEMS Design to Small-Series Production at a Single Location

Fraunhofer ISIT develops resonant 1D and 2D MEMS scanners as well as quasi-static vector scanners for a variety of optical applications. Depending on the requirements, electrostatic or piezoelectric actuation is used.

A key technological approach is wafer-level vacuum packaging. It reduces gas damping, enabling large scan angles at lower drive voltages. Three-dimensional glass lids or glass domes are designed so that unwanted reflections remain outside the relevant field of view.

Scanner design, manufacturing, packaging, electronics, and testing are combined at Fraunhofer ISIT. This enables customized MEMS scanners to be developed from initial design through prototypes and demonstrators to pilot and small-series production.

 

Develop a MEMS Scanner for Your Application

 

Wide Scan Angles Through Optimized Design, Vacuum Packaging, and Control

X-ray image of a MEMS micromirror in a glass package

Fraunhofer ISIT's MEMS scanners combine mechanical design, microstructuring, actuation, vacuum packaging, and position control in an integrated technological approach.

For electrostatically actuated scanners, ISIT uses a two-layer epitaxial polysilicon process with comb drives. Piezoelectric scanners use aluminum scandium nitride (AlScN) as the actuator material.

Vacuum packaging is performed at the 8-inch wafer level and can include getter materials and three-dimensional glass lids. The vacuum reduces gas damping and enables high mechanical quality factors. Integrated position sensors detect mirror motion and provide the basis for closed-loop control.

For wide scan angles, the mirror plate, mechanical design, actuation, and packaging are carefully matched to prevent dynamic deformation and enable precise mirror motion. Key performance specifications of implemented scanners are summarized below. The complete process chain, from design and simulation to manufacturing, packaging, electronics, and testing, is available at the Itzehoe site.

From Wide-Angle LiDAR to Laser Projection

MEMS micromirrors are suitable for applications that require fast and precise light deflection within a compact space.

Miniaturized Borescope for Inspecting Aircraft Turbines

Challenge:

Industrial maintenance of aircraft turbines required a miniaturized optical module capable of measuring surface structures inside the combustion chamber. A two-dimensionally scanned green laser beam needed to produce a spot diameter of approximately 100 µm at a distance of around 500 mm. At the same time, the module had to fit into a cylindrical space with an outer diameter of only 7.6 mm.

Our Solution:

Fraunhofer ISIT developed a compact optical module with a two-dimensionally scanned laser source and an optically decoupled laser receiver. Initially, a green 520 nm laser diode with 15 mW continuous-wave output power in a compact TO33 package was used. It was later replaced by an externally coupled laser fiber with a customized gradient-index lens. The collimated laser beam is directed via a static deflection unit onto a MEMS mirror mounted at a 30° angle. An optically isolated avalanche photodiode receiver with a green-light filter detects the reflected laser light.

Result:

External coupling of the laser beam improved beam quality over a long working distance and reduced heat input into the optical module. This reduced assembly and calibration effort as well as thermal drift of the MEMS mirror. The concept enables the integration of distance measurement, a MEMS mirror, and an RGB camera into a borescope with a diameter of approximately 8 mm.

Other potential applications:

LiDAR for Automotive, Robotics, and Industrial Applications

In a project of Research Fab Microelectronics Germany, a wide-angle LiDAR system featuring a resonant 1D MEMS mirror was developed together with OQmented. The scanner achieves a field of view of up to 180°.

Augmented Reality and Laser Projection

Resonant two-dimensional vacuum-packaged scanners can be used for laser beam scanning systems. ISIT has developed an augmented reality display demonstrator based on a resonant 2D MEMS mirror

Laser Material Processing and Additive Manufacturing

High-speed micromirrors offer potential for compact systems that provide precise laser beam steering and positioning.

Optical Metrology and Telecommunications

Quasi-static scanners can precisely position light and are suitable, among other applications, for optical communications.

Additional potential applications include medical imaging, endoscopy, space applications, head-up displays, and precise optical positioning in quantum technologies.

Wider Field of View with Less Scanner Hardware

The combination of wide scan angles, vacuum packaging, and compact MEMS technology enables scanner solutions for demanding optical systems.

Field of View of Up to 180°

A wide scanning range can reduce the number of scanners required within a system. The developed resonant 1D MEMS mirror achieves a field of view of up to 180°.

High Quality Factor Through Vacuum Packaging

Vacuum packaging reduces gas damping. This enables large deflections at lower drive voltages. Implemented scanners achieve mechanical quality factors of up to 145,000.

Compact Alternative to Rotating Scanners

MEMS mirrors enable compact beam steering without continuously rotating scanner mechanisms. Three-dimensional glass lids also reduce unwanted reflections within the relevant field of view.

Development and Manufacturing from a Single Source

Design, simulation, MEMS manufacturing, packaging, electronics, and testing are available at a single Fraunhofer ISIT location. Prototypes can subsequently be transferred to pilot or small-series production at the Itzehoe site.

Research Projects

Learn more about our related research projects:

Dualeyes