Operating Battery Systems Safely Under Demanding Maritime Conditions
Marine battery storage systems are subjected to high and fluctuating loads. Dynamic load profiles and high charge and discharge currents are compounded by temperature fluctuations, vibrations, and humidity. In underwater applications, extreme ambient pressures may also be a factor.
At the same time, access for maintenance and repair is severely limited, particularly in autonomous underwater vehicles. Battery management must therefore reliably detect critical conditions and support safe operation.
Reliably Determining State of Charge and Operating Limits
The BMS measures cell voltages, current, and temperatures and uses this data to assess the operating condition of the battery system. This includes, in particular, determining the state of charge (SoC).
Cell and module limits must be continuously monitored. This includes overvoltage, undervoltage, overcurrent, short circuits, and overtemperature.
Safely Integrating Different Battery Modules
Modular maritime battery systems can consist of interchangeable or parallel-operated battery units. A BMS must uniquely identify the individual packs, monitor their status, and control their connection to the overall system.
This is particularly relevant when battery packs have different states of charge.
Integrating Battery Storage into the Ship’s Energy System
As electrification increases, battery storage systems are taking on various roles on board. They can power electric or hybrid propulsion systems, absorb peak loads, supply electrical consumers, or provide backup and emergency power.
Battery management must therefore not only manage the battery itself but also provide reliable operational data and interfaces for higher-level energy and power management systems.
Fraunhofer Institute for Silicon Technology