Battery Aging and Characterization

Measurable Battery Aging Has Multiple Causes

Battery cells change during operation. Usable capacity may decrease, internal resistance may increase, and performance may deteriorate. Abnormal cell behavior or premature failures may also occur.

Electrical parameters reveal these changes but do not automatically explain the physical or chemical processes responsible for them.

Distinguishing Symptoms from Root Causes

An increase in internal resistance or a loss of capacity is initially an observed symptom. However, different degradation mechanisms can lead to similar electrical changes.

The objective is therefore to correlate observed abnormalities with physical and material-related findings and distinguish between symptoms, potential mechanisms, and verifiable root causes.

Translating Findings into Concrete Improvements

Understanding the underlying aging or failure mechanism provides a basis for identifying targeted improvement measures.

These may involve cell materials and manufacturing processes, operating limits, charging and discharging strategies, monitoring, or maintenance.

From Observed Abnormalities to Reliable Root Cause Assessment

Our investigations begin with the cell history and its observed behavior. We then combine electrical and electrochemical diagnostic methods with targeted aging tests and physical investigations.

This creates a comprehensive analysis process:

Cell history → Electrical and electrochemical characterization → Aging and diagnostic tests → Post-mortem analysis → Root cause assessment → Recommended actions

Electrochemically Characterizing Cell Condition

New, aged, and abnormal cells are initially examined to determine their electrical and electrochemical properties.

Depending on the specific investigation, these include:

  • Capacity measurement
  • Performance testing
  • Internal resistance
  • Charging and discharging behavior
  • Electrochemical impedance spectroscopy (EIS)

Electrochemical impedance spectroscopy examines the frequency-dependent response of the cell and provides additional information about changes within the cell.

Reproducing Aging Under Controlled Conditions

In defined aging tests, battery cells are exposed to different temperature, state-of-charge, current, and load conditions.

Reference cells and documented initial conditions make it possible to compare and assess changes over time.

Opening and Examining Cells

When further investigation is required, suitable cells are opened under controlled conditions following a safety assessment.

Electrodes, separators, electrolytes, and the overall cell structure can then be examined for mechanical, morphological, chemical, and structural changes.

Systematically Correlating Findings

For root cause analysis, cell history, operating conditions, electrical measurements, visual inspection findings, and material analysis results are evaluated together.

This makes it possible to progressively narrow down which mechanisms explain an observed loss of performance or failure and which root causes are actually supported by the available evidence.

Deriving Improvement Measures from the Analysis

Based on the results, potential improvements can be prioritized.

These may include adjustments to cell materials and manufacturing processes or changes to operating limits, charging methods, monitoring, and maintenance.

Combining Cell Testing and Material Analysis into an Integrated Diagnostic Process

To investigate battery aging, we combine electrical and electrochemical testing methods with controlled cell opening and physical material analysis. The methods are selected according to the cell type, condition, and specific research question.

Aging Battery Cells Under Controlled Conditions

Battery test systems enable cycling, performance testing, and defined aging studies.

Temperature-controlled testing complements these methods and makes it possible to investigate the effects of different ambient temperatures on cell behavior and aging.

Analyzing Electrochemical Changes

Capacity and performance measurements, together with electrochemical impedance spectroscopy, provide information on how relevant cell parameters change during aging.

Measurements taken at different points in time make it possible to track the development of these parameters.

Conducting Post-Mortem Analyses

For suitable cell formats, controlled cell opening and subsequent examination of the individual cell components can be performed.

The analytical methods used depend on the observed failure pattern, cell materials, and investigation objectives.

Correlating Cell History and Analysis Results

Test system data, operational data, and analytical results are evaluated together.

This correlation is essential to avoid considering material findings in isolation and instead relate them to actual operating conditions and changes in electrical cell performance.

From Failure Analysis to Further Battery Development

Aging and root cause analyses are relevant wherever battery cells fail to achieve their expected service life or performance, different cell variants need to be compared, or abnormalities occur during development and operation.

Fault Analysis for Industrial Battery Systems

Challenge:

A typical starting point is an unexpected drop in capacity or performance. In a battery system, an unexpected drop in performance or unusual behavior in individual cells occurs during operation. Electrical measurements indicate the change but do not yet provide a clear explanation for its cause.

Our Solution:

We first analyze the available operational and cell history and characterize selected cells electrically and electrochemically. Depending on the findings, we conduct non-destructive testing, followed by controlled cell disassembly and targeted post-mortem analyses.

Results:

The consolidated data enables a transparent root-cause analysis. From this, measures for troubleshooting and prevention can be derived—for example, for cell and process development, operational management, or the replacement of affected components.

Further Application Possibilities:

Beyond specific failure analysis, these methods support various tasks throughout the battery development and usage lifecycle.

Cell and Technology Development

Aging analyses help identify mechanisms that limit the performance or service life of different cell concepts.

The findings can directly support the further development of materials, electrode designs, and cell structures.

Assessing Quality and Manufacturing Processes

Abnormalities across production batches, suppliers, or different process conditions can be investigated and compared.

This makes it possible to more precisely identify relationships between manufacturing conditions and subsequent cell behavior.

Analyzing Battery Systems

Cell-level findings can be evaluated together with operational data and information on system integration.

This makes it possible to investigate whether factors beyond the cell itself, such as operating strategies or thermal management, have contributed to the observed behavior.

Assessing Remaining Performance and Second-Life Potential

Aging and characterization data provide information about the condition of used cells.

Whether a battery is suitable for further use also depends on the technical requirements and defined acceptance criteria of the respective second-life application.

Going Beyond Detecting Battery Aging to Understanding Its Causes

The key added value lies in combining different levels of investigation. Electrical changes are correlated with cell history, aging conditions, and physical findings. This provides a more robust basis for technical decisions than considering individual performance parameters alone.

Narrowing Down Root Causes More Precisely

Capacity loss or increased internal resistance can have different underlying causes.

Combining electrochemical diagnostics with post-mortem analysis makes it possible to systematically investigate potential mechanisms and narrow them down using additional evidence.

Prioritizing Development Measures

Once the underlying aging mechanism is understood, development resources can be allocated more effectively.

Optimization measures may target materials, manufacturing processes, cell design, or operating strategies.

Preventing Recurring Failures

Root cause analyses focus not only on the affected cell but also on how the failure originated.

This makes it possible to identify measures that prevent similar failures from recurring in manufacturing or operation, or at least reduce their likelihood.

Basing Decisions on Multiple Data Sources

Cell history, electrical measurements, aging tests, and material analyses are brought together.

This reduces the risk of making technical decisions based on a single measurement or isolated material finding.

Directly Supporting Cell and Process Development

The analysis results can be fed directly back into the development process.

Characterization therefore supports not only retrospective failure investigations but also the improvement of future battery cells and manufacturing processes.